HP XP7 Command View Advanced Edition Mainframe Agent Installation and Configuration Guide (TK981-96005, May 2014)

Explanation and actionsMessage textMessage ID
No copy pair information was acquired from the volume to
which the device number Devn was assigned because no
I/O paths are available.
Verify the I/O path settings.
Devn
Device number of the volume whose information acquis-
ition was skipped
No I/O paths are avail-
able for the specified
devices. DEVN=Devn
YKY921W TSO
A REXX script that cannot be used by XP7 mainframe agent
was executed.
Check the REXX Exec library connected to SYSEXEC dd
name.
MFAgent cannot use this
REXX exec library.
YKY999E TSO CON
The command cannot be executed because a GETMAIN
error occurred.
Expand the job execution area, and then re-execute the
command.
nnn (decimal number)
Return code from the GETMAIN macro
mmm (decimal number)
Area size
area (string)
HIGH must be equal to or greater than 16 MB; LOW
must be less than 16 MB.
xxx (decimal number)
Command code of the command that was executing
when the error occurred
0: YKLOAD, or any command (an internal program of
YKP2A)
2: YKSCAN (an internal program of YKP2A)
19: YKQRYDEV (an internal program of YKP2A)
yyy (character string)
Maintenance information
A GETMAIN error oc-
curred. (return
code=nnn, size=mmm,
area=area, cmd=xxx,
pos=yyy)
YKZ201E CON PRT
SC=44
The command cannot be executed because an I/O error
occurred.
message-text (string)
Message text
xxx (decimal number)
Command code of the command that was executing
when the error occurred
See the command code description in the explanation
of the YKZ201E message.
yyy (character string)
Maintenance information
An I/O error occurred.
(detail=message-
text, cmd=xxx,
pos=yyy)
YKZ206E TSO
Messages92