HP XP7 Replication Manager 8.0.0-01 Release Notes

takeover-recovery (resync)
takeover-recovery (recreate)
Operations on the mainframe system
restore
Regarding copy groups maintaining their consistency, if you use a tool other than Replication Manager
to perform a swap operation or takeover (Reverse Resync) operation for either only the copy group
on the open system or only the copy group on the mainframe system, you cannot use Replication
Manager to manage the relevant copy group.
InPrivate browsing in Internet Explorer 9.0
During InPrivate Browsing Mode, the browsing history might remain in the browser.
VMware ESXi 5.0
The following configuration is not supported:
A configuration using a software FCoE adapter and FCoE to connect primary or secondary volumes
to a database server, backup server, and pair management server on a guest OS running in VMware
ESXi 5.0.
Setting up resource groups
Before using the Change Pair Status Wizard, add the user to both of the following resource groups.
Also, before using Pair Configuration Wizard, add the user to both of the following resource groups
for all the copy groups included in the copy topology that is the target of the operation.
Resource groups set up for all the storage systems configured with the copy groups that are the
target of the operation.
Resource groups set up for all the pair management servers managing the copy groups that are
the target of the operation.
HP XP7 RAID Manager installation path for database servers and backup servers
If HP XP7 RAID Manager is installed on a non-system drive, you must change the INSTALL_PATH
parameter in the XP7 RAID Manager linkage definition file (DEFAULT.dat) or change the XP7 RAID
Manager Installation Path setting in the Application Agent Settings window.
In addition, if you execute a VSS backup or manage a replica of Exchange Server, you must set the
system environment variable VSHTCRMENVF on the backup server. For details, see the explanation
about the settings necessary for using VSS in the HP XP7 Replication Manager Application Agent CLI
User Guide.
Editing the journal option settings
If the version of Device Manager installed at a remote site is 7.2.0 to earlier than 7.3.1, editing the
journal option settings of an HP XP P9500 Storage journal group generates the following error
messages:
An attempt to perform journal pool processing has failed. [KAVN00589-E]
An attempt to call the Device Manager server function has failed. (Device
Manager servers error code: KAIC05000, Device Manager servers error
message: An unidentified error has occurred.) [RPM-01004]
To edit the journal option settings, upgrade the Device Manager installed at a remote site to 7.3.1 or
later.
10 Important considerations