HP Insight Management 7.3 Support Matrix
Table Of Contents
- HP Insight Management 7.3 Support Matrix
- Contents
- 1 New and deprecated support
- 2 Management servers
- 3 Management servers in a high-availability environment
- 4 Managed systems hardware
- Public cloud providers
- Supported HP BladeSystem enclosures
- Supported servers
- Supported storage products
- Supported hardware network products
- HP Virtual Connect Enterprise Manager hardware
- Other supported hardware
- 5 Managed system firmware
- 6 Managed systems software
- 7 Managed systems agents and providers
- 8 Support and other resources
- Information to collect before contacting HP
- How to contact HP
- Security bulletin and alert policy for non-HP owned software components
- Registering for software technical support and update service
- HP authorized resellers
- New and changed information in this edition
- Related information
- Typographic conventions
- 9 Documentation feedback
- A Hardware requirements and supported capabilities for Insight Control power management
- B Hardware requirements and caveats for Insight Control server migration
- Storage controllers that Insight Control server migration supports
- Converged network adapters that Insight Control server migration supports
- Network interface cards that Insight Control server migration supports
- File system types that Insight Control server migration supports
- Caveats for Linux server migrations
- Supported storage adapters for manual boot of a destination virtual machine
- Additional Insight Control server migration information
- C Hardware requirements and caveats for Insight Control server provisioning
- D HP-UX CMS requirements
- Acronyms and abbreviations
- Index
Table 64 Requirements and capabilities for HP ProLiant ML servers (continued)
Intelligent
Power
Discovery
3
Data
Center
Power
Control
1,2
Calibrated
Maximum
Power
Power
Metering
Data
Center
Thermal
Mapping
Dynamic
Power
Capping
Power
Regulator
Minimum
system BIOS
version
Minimum
iLO
firmware
version
Server
model
✓✓✓✓✓✓NoneNoneProLiant
ML330
G6
5
✓✓✓✓✓
6
✓5/1/2007iLO 2
version
ProLiant
ML350 G5
1.30 or
later
✓✓✓✓✓✓✓D22
2/23/2009
iLO 2
version
ProLiant
ML350 G6
1.79 or
later
✓✓✓✓✓✓✓iLO 4
version
ProLiant
ML350e
Gen8 1.01 or
later
07/04/2013iLO 4
version
1.30
ProLiant
ML350e
Gen8 V2
✓✓✓✓✓✓✓iLO 4
version
ProLiant
ML350p
Gen8 1.01 or
later
✓✓✓✓✓✓✓P72
08/26/2013
iLO 4
version
ProLiant
ML350p
1.30 or
later
Gen8 (with
Intel EP v2
Xeon
processor)
✓✓✓✓
6
✓5/1/2007iLO 2
version
ProLiant
ML370 G5
1.30 or
later
✓✓✓✓✓✓✓P63
6/20/2009
iLO 2
version
ProLiant
ML370 G6
1.79 or
later
1
Data Center Power Control works only on Primary Addresses of a system and cannot detect a system with a non-primary
address. If a system has IPV4 as a primary address and IPV6 as a non-primary address, Data Center Power Control only
works with the IPV4 address.
2
For VMhost with only an IPV6 address. Data Center Power Control cannot perform a graceful shutdown of guests. It will
only shutdown the hosts.
3
The Intelligent Power discovery feature is not supported when iPDU is configured with iPV6 addresses only
4
You can purchase the RPS option to enable Dynamic Power Capping on this server.
5
This server supports only power/thermal monitoring and capping with certain power-supply options. For detailed
requirements, see the server QuickSpecs.
6
This server supports only Power Capping. It does not support Dynamic Power Capping.
Server requirements and supported capabilities for Insight Control power management 79