HP P6000 Replication Solutions Manager CLI Reference (T3680-96071, June 2012)

Resumes the replication of data from the source to the destination, similar to a
restored connection.
nosuspend
Performs a manual refresh of the DR group properties prior to other operations
that have been specified in this command.
refresh
Specifies the name of the source virtual disk you want removed from the DR
group. The destination virtual disk is removed from the DR group, but it is not
remove_disk
deleted. The destination virtual disk remains as an independent virtual disk. Use
the delete switch to permanently delete the remote virtual disk from the array.
Rules apply; see “Replication guidelines” (page 7).
Pauses data replication from the source to the destination, similar to a failed
connection. Rules apply; see “Replication guidelines” (page 7).
suspend
Pauses data replication from the source to the destination and reverses the roles
of the DR group. The source becomes the destination and the destination
becomes the source. Rules apply; see “Replication guidelines” (page 7).
suspend_and_failover
Indicates the I/O interaction between the source and destination DR group. The
values are synchronous and asynchronous.
writemode
Example
set dr_group group455 name=gr100 wm=asynchronous
SET HOST_AGENT
The SET HOST_AGENT command enables you to modify the host agent.
Syntax
set host_a[gent]|ha <host_agent name>
{ {mount_p[oint]|mp=<mount point>}
[mount_v[olume]|mv=<mount volume>]
[re[scan]|refresh]
[ru[n]=<command>]
[set_isv[irtualmachine]|sisv=<yes or no>]
[unmount_v[olume]|uv=<volume name>] }
|{ {username=<username>}
{password=<password>} }
Switches
Adds a comment to the enabled host.comment
Specifies the name of the enabled host you want to interact with.host agent name
Specifies the mount point. Use this option only if you use the mount_volume or
unmount_volume switches.
mount_point
Specifies the host volume to mount on the enabled host. When you use this switch,
the mount_point switch is required.
mount_volume
Specifies the password for the account that the storage administrator created on the
host before installing the HP Replication Solutions Manager host agent software. For
password
more information, see the HP P6000 Replication Solutions Manager Installation
Guide.
Rescans the enabled host for changes.rescan
Specifies a command to run on the enabled host. The returned information includes
the result code from the enabled host, the command's result code, the enabled host's
run
result, the command's result, the system error, and the system out information for the
command.
Changes the enabled host OS type to VM Guest OS, If the enabled host is set as a
virtual machine, this switch has no effect.
set_isvirtualmachine
30 CLUI commands