FibrChanl-03 (fcoc) Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release Notes Version Number B.11.31.1209 HP Part Number: 5900-2546 Published: November 2012 Edition: 1.
Contents FibrChanl-03 (fcoc) Fibre Channel Mass Storage Driver for HP-UX 11i v3 overview............................3 New and changed features in this release...................................................................................3 New features......................................................................................................................3 Known problems fixed in this version...........................................................................................
This document provides information about the B.11.31.1209 release of the FibrChanl-03 (fcoc) Fibre Channel Mass Storage Driver for HP-UX 11i v3. FibrChanl-03 (fcoc) Fibre Channel Mass Storage Driver for HP-UX 11i v3 overview This release of the document for the FibrChanl-03 (fcoc) Fibre Channel Mass Storage Driver for HP-UX 11i v3 (version B.11.31.1209) documents defect fixes and version changes. New and changed features in this release New features There are no new features in this release.
Table 2 HP-UX March 2012 (AR1203) Fixes (continued) Defect ID Description QXCR1001177226 This corrects a system panic that may occur when a target controller becomes less responsive. QXCR1001180904 This corrects an FCOC driver issue that may result in a system panic when a target controller becomes less responsive.
Table 6 HP-UX March 2011 (AR1103) Fixes Defect ID Description N/A This is the first general release. Table 7 HP-UX November 2010 (WEB1011) Fixes Defect ID Description N/A There are no known problems fixed in this version. NOTE: 11i v3. WEB1011 is the initial controlled availability release of FibrChanl-03 (fcoc) on HP-UX Known problems and limitations This section provides a list of known problems and limitations as known to HP at time of publication.
At this point, the blade should be booted from HP-UX and be up and running. However, the blade remains in Ignite-UX and waits to be re-installed again. NOTE: In order to reproduce the problem, a power cycle is necessary between the un-assign and re-assign profile steps. Without the power cycle between the un-assign and re-assign profile, the problem does not occur. • FCoE Boot From SAN for Firmware version 4.1.450.
4. A list of all the adapters in the system is displayed. Your list may vary depending on the installed adapters. Locate the adapter you want to configure. Use the up/down arrows on your keyboard to select it, and press Enter. 5. The Emulex Adapter Configuration Main Menu screen comes up. Select Set Boot From SAN. A Disable Enable menu is displayed. Use the arrow keys to select the Enable option and press Enter. The selection is updated to NVRAM and the current setting is displayed.
6. 7. 8. On the same Emulex Adapter Configuration Main Menu screen, select Back to Display Adapters and RECONNECT DEVICES and press Enter. Type s to save the changes. Exit the Emulex utility. Control B to go into cm and type rs to reset the system. Compatibility and installation requirements This section describes the compatibility information and installation requirements for this release. For specific installation instructions, refer to the installation guide specific to your FibreChannel card.
NOTE: The FC-COMMON.FC-SNIA fileset is part of the CommonIO bundle. If FC-COMMON.FC-SNIA (1103 or later) is not present on a system, swinstall of the FC-FCOC product will display errors. If you ignore the errors and proceed with the swinstall, the FC-FCOC.FC-FCOC-RUN fileset will not be installed. Driver versions The following table lists all the driver versions of the fcoc driver on HP-UX 11i v3 with their associated release names and dates.