FibrChanl-03 (fcoc) B.11.31.1209 Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release Notes

At this point, the blade should be booted from HP-UX and be up and running. However, the
blade remains in Ignite-UX and waits to be re-installed again.
NOTE: In order to reproduce the problem, a power cycle is necessary between the un-assign
and re-assign profile steps. Without the power cycle between the un-assign and re-assign
profile, the problem does not occur.
FCoE Boot From SAN for Firmware version 4.1.450.7 or higher
In a non-Virtual Connect FlexFabric configuration, a system configured with a FCoE device in
the EFI Boot Manager should be able to boot by selecting the FCoE Boot Entry. If the system
does not have a FCoE device in EFI Boot Manager, the “Set boot from SAN” controls the
FCoE boot device mapping behavior. The “Set boot from SAN” should be set to “Enable to
allow booting from the FCoE boot device.
In a Virtual Connect FlexFabric configuration, a system with the Fibre Channel HBA boot
parameters defined on the server profile will configure the FCoE boot device in EFI. A FCoE
Boot Entry is required to boot the device from the EFI Boot Manager. If the system does not
have the Fibre Channel HBA boot parameters defined, the boot behavior is similar to a non-VC
FlexFabric configuration above. For additional information about setting the Fibre Channel
HBA boot parameters with Virtual Connect FlexFabric, refer to the HP Virtual Connect FlexFabric
Cookbook (Part Number c02616817).
FCoE Boot From SAN for Firmware version 4.356.3 or lower
To enable booting through the fcoc driver, the following steps need to be performed once.
To start the Emulex Configuration Utility via the Human Interface Infrastructure (HII):
1. Launch the Device Manager. A front page is displayed.
2. Select Emulex Configuration Utility Ver:X.XXXXX and press Enter.
3. When the Emulex Configuration Utility screen is displayed with Emulex Configuration
Setup Utility selected, press Enter.