HP StorageWorks Fabric OS 5.2.3 Release Notes (AA-RWEYD-TE, November 2007)

Memory leak caused weblinker to restart when performing a congure
port status from Fabric Manager and was in error code path.
Fixed per Fabric OS 5.2.3.
Panic occurs when running Management Ser ver commands
GPT/GPPN/GPS
/GAPNL continuously due to race condition.
Fixed per Fabric OS 5.2.3.
Speed auto negotiation does not always bring the ports to 4Gb speed
with a specic4GbHBA.Appliestoall4Gbswitches.
Fixed per Fabric OS 5.2.3.
Inafabric,withswitchinAccessGatewaymodeconnectedtoFOS
switch, after rmware upgrade from pre-FOS v5.1.0 to FOS v5.1.0
or higher on FOS switch, NPIV no long er works, and it reports
[AG-1001] on the FOS switch; HAfailover/haboot on the FOS switch
and portdisable/p ortenable on the AG port on the AG switch can
recover the ports.
Fixed per Fabric OS 5.2.3.
Switch pani
cs with name server daemon (nsd) core dump when
running iS
CSI fclunquery command through application due to
unexpected PLOGI from embedded port being forwarded to n ame
server fo
rzonecheck.
Fixed per F
abric OS 5.2 .3.
With FC Tape Pipelining enabled on a 400 MP Router & FR4-18i
with a block size greater than 128Kb, the tape pipelining command
performancecausedbackupdatatobecomeunreadable.
Fixed per Fabric OS 5.2.3.
Compact Flash (CF) becomes inaccessible- as end_request: I/O error
duetoraceconditionwithlevelofinterrupts.
Fixed per Fabric OS 5.2.3.
The SNMP
d command crashed when trying a specicSNMPOIDget
of an attribute to connUnitEntry table.
Fixed per Fabric OS 5.2.3
Switch panic with watchdog exception while in CPU IDLE loop in very
rare cases. Only affects 2/128 and all 4Gb switches.
Fixed per Fabric OS 5.2.3.
Subnetted FCIP port will only connect to three out of every four IP
addresses due to sendin g Mac level broadcast frames instead of the
Router’s MAC address. Impacts 400 MP Router and FR4-18i.
Fixed per Fabric OS 5.2.3.
HP StorageWorks Fabric OS 5.2.3 release notes
23