Brocade OS Command Reference Manual Supporting Fabric OS v6.0.0 (53-1000599-01, October 2007)

92 Fabric OS Command Reference
53-1000599-01
configure
2
System Settings
The following parameter is configurable under System settings:
TABLE 10
system.blade.bladeFaultOnHwErrMsk
If this field is set to a value other than 0, then any non fatal HW ASIC data
parity error will cause the problem blade to be powered off.
Examples To enable signed firmware download on a disabled switch:
switch:admin> configure
Configure...
Fabric parameters (yes, y, no, n): [no]
Virtual Channel parameters (yes, y, no, n): [no]
F-Port login parameters (yes, y, no, n): [no]
Zoning Operation parameters (yes, y, no, n): [no]
RSCN Transmission Mode (yes, y, no, n): [no]
Arbitrated Loop parameters (yes, y, no, n): [no]
System services (yes, y, no, n): [no]
Portlog events enable (yes, y, no, n): [no]
ssl attributes (yes, y, no, n): [no]
rpcd attributes (yes, y, no, n): [no]
cfgload attributes (yes, y, no, n): [no] y
Enforce secure config Upload/Download (yes, y, no, n): [no]
Enforce signature validation for firmware (yes, y, no, n): [no] y
webtools attributes (yes, y, no, n): [no]
System (yes, y, no, n): [no
:See Also configDefault, configShow, ipAddrSet, portCfgLongDistance, switchDisable, switchEnable, upTime
Field Type Default Range
system.blade.bladeFaultOn
HwErrMsk
Number 0x0 0x0 to 0xffff