Brocade OS Command Reference Manual Supporting Fabric OS v6.0.0 (53-1000599-01, October 2007)

Fabric OS Command Reference 99
53-1000599-01
diagClearError
2
diagClearError
Clears the diagnostics failure status.
Synopsis diagclearerror [[--slot] slotnumber] -all
Description Use this command to clear the diagnostics failure status.
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands This command has the following operand:
--slot slotnumber Specify the slot to clear the diagnostics failure status. The default is set to 0
and designed to operate on fixed-port-count products.
-all If specified, all blades clear
.
If no operand is specified, the default is to clear all bad port flags.
Examples To clear the diag software flag:
switch:admin> diagclearerror 8
ERROR: DIAG CLEARERR
Diagnostics Errors Cleared, port: 8/31
Err# 0120041 081F
See Also none