Brocade OS Command Reference Manual Supporting Fabric OS v6.0.0 (53-1000599-01, October 2007)

112 Fabric OS Command Reference
53-1000599-01
diagStatus
2
diagStatus
Displays currently running diagnostic tests.
Synopsis diagstatus [slotnumber]
Description Use this command to display currently running diagnostic test names.
This command is ignored on newer platforms such as the FR4-18i, FA4-18, FC10-6, Brocade 7500,
4900, and AP 7600. The command is allowed to run on these platforms to maintain consistency
across mixed blade environments, but it does not affect the operations of the switch.
Operands The follow is optional:
slotnumber Specifies the slot to display. If omitted, all blades in the system are assumed.
Examples To display currently running diagnostic tests:
switch:admin> diagstatus
Diagnostic status for slot: 1.
Diag executing "NONE"
Diagnostic status for slot: 2.
Diag executing "NONE"
Diagnostic status for slot: 3.
Diag executing "NONE"
Diagnostic status for slot: 4.
Diag executing "NONE"
(output truncated)
See Also none