Brocade OS Command Reference Manual Supporting Fabric OS v6.0.0 (53-1000599-01, October 2007)

Fabric OS Command Reference 247
53-1000599-01
fwSetToCustom
2
fwSetToCustom
Sets boundary and alarm levels to custom values.
Synopsis fwsettocustom
Description Use this command to set boundary and alarm levels to custom values for all classes and areas in
Fabric Watch.
Notes This command requires a Fabric Watch license.
The execution of this command is subject to Admin Domain restrictions that may be in place.
Operands none
Examples To set alarm levels to custom values:
switch:admin> fwsettocustom
Committing configuration...done.
See Also fwSetToDefault