Brocade OS Command Reference Manual Supporting Fabric OS v6.0.0 (53-1000599-01, October 2007)

Fabric OS Command Reference 333
53-1000599-01
miniCycle
2
-spd_mode mode Specifies the speed mode for the test. This parameter is only used for Bloom
and Condor ASIC-based products, for which this parameter controls the speed
at which each port operates. For 1 Gbit/sec-only products, this parameter is
ignored. The exact operation of modes 5 through 8 depends on the loopback
mode selected. When speed modes 5 through 8 are used with cables, they
must be connected EVEN->ODD or the test fails.
0 Run test at 1 Gbit/sec, 2 Gbit/sec, and 4 Gbit/sec (default).
1 Set all port speeds to lock at 1 Gbit/sec.
2 Set all port speeds to lock at 2 Gbit/sec.
4 Set all port speeds to lock at 4 Gbit/sec.
For -lb_mode set to 1, the following speed modes are available to test the speed negotiation.
3 Set all even ports' speed for auto-negotiate. Set all odd ports' speed for 1
Gbit/sec.
4 Set all even ports' speed for auto-negotiate. Set all odd ports' speed for 2
Gbit/sec.
5 Set all odd ports' speed for auto-negotiate. Set all even ports' speed for 1
Gbit/sec.
6 Set all odd ports' speed for auto-negotiate. Set all even ports' speed for 2
Gbit/sec.
For -lb_mode set to 2, the following speed modes are available to test FIFO underrun.
3,5 Set all even ports' speed for 2 Gbit/sec. Set all odd ports' speed for 1
Gbit/sec.
4,6 Set all even ports' speed for 1 Gbit/sec. Set all odd ports' speed for 2
Gbit/sec.
-splb_mode 0 | 1 Specifies a special loopback mode for minicycle.The regular minicycle test
routes two port together and spins frames between them. In splb_mode,
ports are not routed. Each port spins frames to themselves. This test
resembles a spinning version of porLoopBackTest. Note that in splb_mode,
the test will do one pass only on path 8.
splb_mode is either on (1) or off (0). The default is off (0).
-ports itemlist Specifies a list of blade ports to test. By default, all the blade ports in the
specified slot (--slot) are used. Refer to itemlist for further details. If all ports
in the ASIC pair are not specified, only paths between selected ports are
tested.
ASIC-pair 0: -ports 0-15
ASIC-pair 1: -ports 16-31
ASIC-pair 2: -ports 32-47
ASIC-pair 3: -ports 48-63
Examples To run a functional test on slot 1 using external (SERDES) loopback:
switch:admin> minicycle --slot 1 -lb_mode 2