Brocade OS Command Reference Manual Supporting Fabric OS v6.0.0 (53-1000599-01, October 2007)

Fabric OS Command Reference 443
53-1000599-01
portCfgISLMode
2
Operands This command has the following operands:
slotnumber For bladed systems only, specify the slot number of the port to display,
followed by a slash (/).
portnumber Specify the port number to display, relative to its slot for bladed systems. Use
switchShow to list valid ports.
mode Specify 1 to enable ISL R_RDY mode. Specify 0 to disable ISL R_RDY mode.
Examples To enable ISL R_RDY mode on a port:
switch:admin> portcfgislmode 1/3, 1
ISL R_RDY Mode is enabled for port 3. Please make sure the PID
formats are consistent across the entire fabric.
To disable ISL R_RDY mode on a port:
switch:admin> portcfgislmode 1/3, 0
See Also configure, portCfgLongDistance, portCfgShow