Brocade OS Command Reference Manual Supporting Fabric OS v6.0.0 (53-1000599-01, October 2007)

490 Fabric OS Command Reference
53-1000599-01
portLogShow
2
enable Mode: 0 normal; non-zero loopback
Tx & Rx Header words 0,1,4 (R_CTL,D_ID,S_ID,OX_ID,RX_ID) and the first payload
word
reject FC-PH reject reason
busy FC-PH busy reason
ctin Argument 0 is divided into two 16-bit fields:
[A] a bit map indicating whether subsequent args are valid (0001 means
argument 1 is valid, 0003 means arguments 1 and 2 are valid).
[B] the CT-based service command code.
Argument 1 is the first word of the CT payload, if applicable (as specified in
[A]).
Argument 2 is the second word of the CT payload, if applicable (as specified
in [A]).
ctout Argument 0 is also divided into two 16-bit fields:
[A] a bit map indicating whether subsequent args are valid (0001 means
argument 1 is valid, 0003 means arguments 1 and 2 are valid).
[B] the CT command code indicating whether an accept (8002) or a reject
(8001).
If [B] is an accept, argument 1 and 2 represents the first and second words of
the CT payload, if applicable (as specified in [A]).
If [B] is a reject, argument 1 contains the CT reject reason and explanation
code.
errlog Error type (refer to errShow)
loopscn The meaning further depends on each loop state:
OLP Offline reason code, usually zero
LIP Reason code for LIPs initiated by FL_Port, if the code value is 800x (x =
[1,0xc], see below), or the lower two bytes of the LIP received, if the code
value is other than 800x
LIM Usually zero
BMP Memory address for the loop bitmap
OLD Usually zero
TMO Encoded value of the state when loop init timed out This value is usually
equal to the first word of a loop init frame payload. Other possible values
include:
2 LIP (req. INITIALIZING) timeout
94F0F0ARB(F0) timeout
40 CLS timeout