Brocade OS Command Reference Manual Supporting Fabric OS v6.0.0 (53-1000599-01, October 2007)

628 Fabric OS Command Reference
53-1000599-01
switchShow
2
sw shortwave laser
wlongwave laser
cu copper
id serial ID
Speed The speed of the port:
1/8G 125 Mbit/sec
1/4G 250 Mbit/sec
1/2G 500 Mbit/sec
1G 1 Gbit/sec fixed transfer speed
N1 1 Gbit/sec negotiated transfer speed
2G 2 Gbit/sec fixed transfer speed
N2 2 Gbit/sec negotiated transfer speed
4G 4 Gbit/sec fixed transfer speed
N4 4 Gbit/sec negotiated transfer speed
8G 4 Gbit/sec fixed transfer speed
N8 4 Gbit/sec negotiated transfer speed
AN Auto negotiating
UN Unknown
Port State Port state information:
No_Card No interface card present.
No_Module No module (GBIC or other) present.
Mod_Val Module validation in process.
Mod_Inv Invalid module.
No_Light Module not receiving light.
No_Sync Module receiving light but out of sync.
In_Sync Module receiving light and in sync.
Laser_Flt Module signaling a laser fault.
Port_Flt Port marked faulty.
Diag_Flt Port failed diagnostics.
Lock_Ref Locking to the reference signal.
Testing Running diagnostics.
Offline Connection not established (for virtual ports only).
Online Port is up and running.
Proto Protocol support by GbE port.
ISCSI Ports support ISCSI.