Table 6 Fabric OS 6.3.2 closed defects (continued)
Fixed in Fabric OS 6.3.2.In an encryption environment, tape devices intermittently show offline
condition to the host. Observed in setup where some Physical Initiators do
not register as FC4 type devices and some do.
Fixed in Fabric OS 6.3.2.On 4Gb switches, when a frame comes into the embedded port and there
is no memory to hold it temporarily, the switch panics. This is likely to happen
when there are spurious interrupts from a device.
Fixed in Fabric OS 6.3.2.When FCP_CONF command is dropped, the restore job from tape is unable
to continue and complete successfully. Applies only to the 1606 Extension
switch and Multiprotocol Extension blade.
Fixed in Fabric OS 6.3.2.CP-1250 heartbeat is dead on Multiprotocol Router blade, which results in
a CP panic and reboot.
Fixed in Fabric OS 6.3.2.If per port NPIV limit on AG is set to greater than 26, some F_Ports may not
come online and stay as G_Ports.
Fixed in Fabric OS 6.3.2.The configdefault command on the switch is not setting default fcmap
to 0x0efc00. If configdefault is issued after slotpoweroff or after
removing a blade from a slot, configdefault can fail without setting the
default value for fcmap, thereby not returning the switch to the default factory
state. This affects the 2408 FCoE switch and 10/24 FCoE blade only.
Fixed in Fabric OS 6.3.2.Open SSL is updated to address CVD-2009-3555/CERT advisory 120541
(TLS and SSL protocol vulnerability).
Fixed in Fabric OS 6.3.2.Tape drives fail when running over FCR with EX_Ports in Open mode. The
REC accept payload is incorrect. If host to tape I/O traverses FCR and
includes an edge fabric, the tape drives run for a bit and then fail because
REC ACC is not processed correctly if the EX_Port is operating in IM3/Open
mode.
Fixed in Fabric OS 6.3.2.ARP goes away and Neighbor Discovery timeouts occur on routed networks
after pulling GE cables during heavy traffic. No end-to-end connection can
be established. Tunnel 20 (GE4) failed to recover. Switch had to be reset to
recover.
Fixed in Fabric OS 6.3.2.With tape encryption, backup to all clear text containers using netbackup
in a Multiplex/stream environment results in an encryption SAN switch fault,
causing tape flows to halt.
Workaround prior to upgrade: Use
VE_Ports 16-31.
Tunnel creation failed with error message Unable to add more FCIP
circuits to this tunnel when using VE_Ports 12-15 on DC SAN
Fixed in Fabric OS 6.3.2.
Backbone director with 2 or more Multiprotocol Extension blades. Not an
issue with DC04 SAN director or 1606 extension switch.
Fixed in Fabric OS 6.3.2.Unable to disable default zone from Mi10k in interop fabric in IM2 mode
after zone merge failure.
Workaround prior to upgrade: Disable
either or both "Locked G_Port" and
Bottleneckmon cannot be enabled on F_Ports with Locked G_Port and
Disabled E_Port enabled in portcfg.
"Disabled E_Port" features, but note that
this operation is disruptive.
Fixed in Fabric OS 6.3.2.
Workaround prior to upgrade: Disable
FICON emulation.
Abort in FICON Tape Read emulation if Attention status is received between
status and status accept.
Fixed in Fabric OS 6.3.2.
Fabric OS 6.3.2a fixes
Table 7 (page 46) lists defects closed in the Fabric OS 6.3.2a firmware release
Fabric OS 6.3.2a fixes 45