HP B-series Fabric OS 6.3.2e Release Notes (5697-1816, March 2012) - includes all 6.3.2x versions

Table 8 Fabric OS 6.3.2b closed defects (continued)
Fixed in Fabric OS 6.3.2b.In an AG fabric, DXFM/FM/SMI proxy switch sends a GAGI request to
another switch in the fabric with Brocade_AG query. This sometimes triggers
verify and floods the raslog, which may cause high CPU load and switch
panic.
Fixed in Fabric OS 6.3.2b.With Virtual Fabrics (VF) enabled and Radius server configured, customers
may see RAS-1004 Software 'Verify' errors logged every 3 minutes on each
VF on a switch being managed by DCFM or Web Tools. The errors fill the
RASLOG and eventually cause an FFDC event in other system modules due
to “too many open files. Virtual Fabrics can be configured on the following
switches:
HP DC SAN Backbone Director Switch PP
HP DC04 SAN Director Switch
HP 8/80 Base 48-ports Enabled SAN Switch
HP 8/80 Power Pack+, 48-ports SAN Switch
HP 8/40 Base 24-ports Enabled SAN Switch
HP 8/40 Power Pack+ 24-ports SAN Switch
Fixed in Fabric OS 6.3.2b.SW MIB counters such as Link Error State Block, Port Level Performance/Error,
and other similar objects are available through CLI commands, but not through
SNMP.
Fixed in Fabric OS 6.3.2b.Tape performance is degraded after a tape drive has been idle for a few
hours and then traffic is restarted on an HP 1606 SAN Extension Switch.
Fixed in Fabric OS 6.3.2b.Users are unable to create a Certificate Signing Request (CSR) on a switch
with only an IPv6 address configured.
Fixed in Fabric OS 6.3.2b.The output of the switchstatusshow command reports an invalid switch
status rather than the "marginal" status when application blades go down.
This is caused by the Fabric Watch blade handler monitor mishandling the
status of application blades.
Workaround prior to upgrade: Use the
slotstatsclear command instead of
the statsclear command.
Fabric Watch reports TX/RX performance over 100% after executing the
statsclear command.
Fixed in Fabric OS 6.3.2b.
Fixed in Fabric OS 6.3.2b.The LED for online trunked F_Ports goes from a steady green to off after a
code upgrade or hareboot/hafailover.
Fixed in Fabric OS 6.3.2b.For both portstats and SNMP MIB output commands, counters quickly wrap
on GE_Ports of an HP 1606 SAN Extension Switch or an HP DC SAN Director
Multiprotocol Extension Blade.
Fabric OS 6.3.2c fixes
Table 9 (page 49) lists defects closed in the Fabric OS 6.2.3c firmware release.
Table 9 Fabric OS 6.3.2c closed defects
SolutionClosed defect summary
Fixed in Fabric OS 6.3.2c.Frames received on shared area port trunks are improperly routed on an HP
SAN Director 48-port 8Gb FC Blade in an HP DC SAN Backbone Director.
This may occur after the remote trunk master goes offline and then comes
back online.
Fixed in Fabric OS 6.3.2c.A switch panic/director HA Failover may occur due to resource contention
when TopTalker is monitoring traffic flows.
Fixed in Fabric OS 6.3.2c.Customers are unable to access a device after FCIP links bounce multiple
times. Frames with same SID/DID were sent to the device after the proxy
translation failed in a backbone to edge FCR setup.
Fabric OS 6.3.2c fixes 49