HP B-series Fabric OS 6.3.2e Release Notes (5697-1816, March 2012) - includes all 6.3.2x versions

Table 9 Fabric OS 6.3.2c closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 6.3.2c.After upgrading a fabric switch from Fabric OS from 6.2.x to 6.3.x, the
N_Port was stuck in G_Port when the fabric switch is attached to an Access
Gateway switch with QoS enabled.
Fixed in Fabric OS 6.3.2c.FAN frames are not being sent by the switch to loop devices after LIP when
fcAL.fanFrameDisable is set to 0.
Fixed in Fabric OS 6.3.2c.A reboot of a host on one port group may adversely affect another host in
a different port group causing loss of connectivity to their storage.
Fixed in Fabric OS 6.3.2c.A switch with busy management applications may run into a race condition
when more than one RPC connection gets established simultaneously. This
may cause multiple connections to free a shared object twice and trigger an
rpcd panic.
Fixed in Fabric OS 6.3.2c.Access Gateway trace data lacks enough information for path loss
debugging.
Fixed in Fabric OS 6.3.2c.SW MIB counters such as Link Error State Block, Port Level Performance/Error,
and other similar objects are available through the CLI but not through SNMP.
Fixed in Fabric OS 6.3.2c.After a device performs a LOGO, followed by port offline and online events,
the switch route is not properly re-established, and the host cannot discover
targets.
Fixed in Fabric OS 6.3.2c.Due to an incorrect internal counter logic, PORT-1003 port faults are
erroneously being reported in the RASLOG.
Fixed in Fabric OS 6.3.2c.After configuring the SCC Policy only on an edge switch, then removing the
front domains of the FCR from the SCC followed by disabling/enabling the
edge switch, the F_Ports get disabled with the following message:
2010/08/20-16:19:45, [SEC-1187], 1433, FID 128, INFO,
T5300_161, Security violation: Unauthorized switch
20:00:00:05:1e:0a:54:ca tries to join fabric.
Fixed in Fabric OS 6.3.2c.There is currently no functionality to disable the IPv6 interface when duplicate
addresses are detected.
Fixed in Fabric OS 6.3.2c.Customers may experience false fan related errors on the HP 2408 24-10GbE
w/8-8Gb FC Base FCoE Switch.
Fixed in Fabric OS 6.3.2c.SNMP shows MIB connUnitPortEntries only for ports that have SFPs installed.
Fixed in Fabric OS 6.3.2c.Kernel panic encountered while accessing compact flash.
Fixed in Fabric OS 6.3.2c.Pv6 named Certificate Signing Request (CSR) files may not be FTP'd to some
Windows based ftp server because of the presence of . in the filename.
Fixed in Fabric OS 6.3.2c.Customers may observe a temporary laser fault with SFPs, or other I2c access
retries during heavy load.
Fixed in Fabric OS 6.3.2c.After replacing a drive on an FL_Port, the initiator cannot discover the device.
The newly replaced device on the Loop port does not register with name
server properly.
Fixed in Fabric OS 6.3.2c.When BE credit is lost, customers need to reseat the blade to recover.
Fixed in Fabric OS 6.3.2c.seccertutil genkey reports "Configure a Valid IPv4 or IPv6 address" when
there already is a valid IPv6 address.
Fixed in Fabric OS 6.3.2c.The severity for the RASLOG AN-1003 error is raised from WARNING to
ERROR in order to provide an easy interface for customers to trap it through
SNMP. Customers who do not want to see this RAS log should leave
Bottleneck Detection disabled.
Fixed in Fabric OS 6.3.2c.If SNMP polling by management application is too frequent, the CPU may
become overloaded resulting in other operational failures not directly related
to this functionality.