HP B-series Fabric OS 6.3.2e Release Notes (5697-1816, March 2012) - includes all 6.3.2x versions

Table 9 Fabric OS 6.3.2c closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 6.3.2c.There previously was no easy way to diagnose link level errors on backend
ports. This release includes a new diagnostic command, pterrshow, to display
ASIC backend errors.
Fixed in Fabric OS 6.3.2c.Ports cannot negotiate at 8G speed on the following switches:
HP 8/8 Base (0) e-port SAN Switch
HP 8/8 (8)-ports Enabled SAN Switch
HP 8/24 Base 16-ports Enabled SAN Switch
HP 8/80 Base 48-ports Enabled SAN Switch
HP 8/80 Power Pack+, 48-ports SAN Switch
HP EVA4400 embedded switch module
8Gb Brocade Brocade 8Gb SAN Switch for HP BladeSystem c-Class
HP 1606 SAN Extension Switch
Fixed in Fabric OS 6.3.2c.Issuing an HA failover command on either of the HP SN8000B SAN
Backbone Directors (8-Slot or 4-Slot) may result in internal routing related
errors for ICL ports.
Fabric OS 6.3.2d fixes
Table 10 (page 51) lists defects closed in the Fabric OS 6.2.3d firmware release.
Table 10 Fabric OS 6.3.2d closed defects
SolutionClosed defect summary
Fixed in Fabric OS 6.3.2d.Upon disabling one link of a two-port trunk, the HP DC SAN Backbone
Director Switch encountered both CPs panicking within three minutes. This
is a topology and upgrade path specific issue.
Fixed in Fabric OS 6.3.2d.Hosts may lose access to storage after changing the FCR backbone domain
ID on an HP DC SAN Backbone Director Switch or HP DC04 SAN Director
Switch with an HP SAN Director 48-port 8Gb FC Blade or an HP DC SAN
Director 64-port 8Gb FC Blade. The frames drops occur on the backend
ports of the blades.
Fixed in Fabric OS 6.3.2d.A switch running in Access Gateway (AG) mode does not clean up the fabric
channel frame exchange properly. This occurs when FLOGI/FDISC comes
in from different ports together with same exchange ID (OX-ID).
Fixed in Fabric OS 6.3.2d.A host is unable to access the target when connected to a 4 Gb switch during
a specific storage device power-up sequence.
Fixed in Fabric OS 6.3.2d.SNMP Throttling commands are not available for admin user.
Fabric OS 6.3.2e fixes
Table 11 (page 51) lists defects closed in the Fabric OS 6.2.3d firmware release.
Table 11 Fabric OS 6.3.2e closed defects
SolutionClosed defect summary
Fixed in Fabric OS 6.3.2e.A switch panic may occur when there are GE_Ports with SFPs installed on
an HP DC SAN Director Multiprotocol Extension Blade or an HP 1606 SAN
Extension Switch.
Fixed in Fabric OS 6.3.2e.An unstable link may trigger continuous timeout/discard frame/un-routable
frame tracing to the CPU for processing on the HP StorageWorks 4/256
SAN Directors.
Fabric OS 6.3.2d fixes 51