HP StorageWorks Fabric OS 6.x administrator guide (5697-7344, March 2008)

254 Using the FC-FC routing service
5. Enable the port by issuing the portEnable command.
switch>:admin_06> portenable 10/13
If the port was persistently disabled, use the following command to enable the port:
switch:admin_06> portcfgpersistentenable 10/13
Connect IFL1 and verify EX_PORT connectivity. Repeat for all Brocade fabric IFLs.
Connect IFL (n) for the M-EOS fabric and verify EX_PORT connectivity. Repeat for all M-EOS fabric
IFLs.
6. Log in to the FC router and issue the switchShow command to display the M-Series switch that is
connected to the FC router EX_Port. The following example illustrates the use of the switchShow
command and its output.
switch>:admin_06> switchshow
switchName: b48000_5x_1
switchType: 42.2
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 3
switchId: fffc03
switchWwn: 10:00:00:60:69:e4:00:86
zoning: ON (test)
switchBeacon: OFF
blade3 Beacon: OFF
blade8 Beacon: OFF
blade10 Beacon: OFF
FC router: ON
FC router BB Fabric ID: 1
Index Slot Port Address Media Speed State Proto
===================================================
112 10 0 037000 id N4 No_Light Disabled (Persistent)
113 10 1 037100 id N4 No_Light Disabled (Persistent)
114 10 2 037200 id N4 No_Light Disabled (Persistent)
115 10 3 037300 id N4 No_Light Disabled (Persistent)
116 10 4 037400 id N4 No_Light Disabled (Persistent)
117 10 5 037500 id N4 No_Light Disabled (Persistent)
118 10 6 037600 id N4 No_Light Disabled (Persistent)
119 10 7 037700 id N4 No_Light Disabled (Persistent)
120 10 8 037800 id N4 No_Sync Disabled (Persistent)
121 10 9 037900 id N2 No_Light
122 10 10 037a00 id N2 No_Light
123 10 11 037b00 id N2 No_Light
124 10 12 037c00 id N2 Online EX-Port
10:00:00:05:1e:34:e0:6a "b4100_5x_1" (fabric id = 41 )
125 10 13 037d00 id N2 Online EX-Port
10:00:08:00:88:03:53:fc "mcd_37" (fabric id = 37 )
126 10 14 037e00 id N2 No_Light
127 10 15 037f00 id N2 No_Light
240 10 16 03f000 -- -- Offline Disabled (Persistent)
241 10 17 03f100 -- -- Offline Disabled (Persistent)
242 10 18 03f200 -- -- Offline Disabled (Persistent)
243 10 19 03f300 -- -- Offline Disabled (Persistent)
...this example has been truncated
7. You can now physically attach your ISLs from the 400 MP Router and 4/256 SAN Director or DC
Director with an FR4-18i blade to the switches.
ISLs apply only to Brocade switches that are not connected as an edge fabric (IFLs). When an M-Series
switch is present, it is assumed that you are creating an edge fabric.