HP StorageWorks Fabric OS 6.x administrator guide (5697-7344, March 2008)

Fabric OS 6.x administrator guide 465
4. Repeat steps 1 through 3 for the blade or switch on the other end of the FC fastwrite path.
5. Use the portshow command to verify that FC fastwrite is enabled.
rack1_6a1:root> portshow 3/3
portName:
portHealth: HEALTHY
Authentication: None
portDisableReason: None
portCFlags: 0x1
portFlags: 0x20b03 PRESENT ACTIVE F_PORT G_PORT U_PORT
LOGICAL_ONLINE LOGIN NOELP ACCEPT
portType: 10.0
portState: 1 Online
portPhys: 6 In_Sync
portScn: 32 F_Port
port generation number: 0
portId: 022300
portIfId: 43320004
portWwn: 20:23:00:60:69:80:04:8a
portWwn of device(s) connected:
10:00:00:00:c9:2f:68:4d
Distance: normal
portSpeed: N2Gbps
LE domain: 0
FC Fastwrite: ON
Interrupts: 18 Link_failure: 0 Frjt:
0
Unknown: 0 Loss_of_sync: 2 Fbsy:
0
Lli: 12 Loss_of_sig: 4
Proc_rqrd: 13 Protocol_err: 0
Timed_out: 0 Invalid_word: 0
Rx_flushed: 0 Invalid_crc: 0
Tx_unavail: 0 Delim_err: 0
Free_buffer: 0 Address_err: 0
Overrun: 0 Lr_in: 2
Suspended: 0 Lr_out: 0
Parity_err: 0 Ols_in: 0
2_parity_err: 0 Ols_out: 2
CMI_bus_err: 0
Port part of other ADs: N