64 Operating
Migration parameters
Figure 74 Migration dialog
NOTE: If no archive is defined, the job contains no migration operation.
Usually files are migrated to a maximum of two FMA archives to have a automatic failover if an archive is
not available.
Table 10 Migration dialog
Setting Description
Minimum file size: Define a minimum file size for the migration operation. The value can be specified in
bytes, kilobytes, megabytes, or gigabytes.
Minimum time interval
(modified):
Define minimum time interval since the file was last modified for the migration
operation to start. The value can be specified in seconds, minutes, hours, or days.
Minimum time interval
(accessed):
Define minimum time interval since the last file access for the migration operation to
start. The value can be specified in seconds, minutes, hours, or days.
System: If this option is selected, no files with system attribute will be migrated.
Hidden: If this option is selected, no hidden files will be migrated.
Read Only: If this option is selected, no read-only files will be migrated.
Archive: If this option is selected, no files with active-archive bit will be migrated.
Compressed: If this option is selected, no files with active-compressed bit will be migrated.