HAFM SW 08.08.00 HP StorageWorks HA-Fabric Manager User Guide (AA-RS2CH-TE, August 2006)

HA-Fabric Manager user guide 241
Cannot retrieve port
statistics.
Port statistics cannot be
retrieved by the Element
Manager because the
Ethernet link is down or
busy.
Retry the operation later. If the
condition persists, contact the next
level of support.
Cannot retrieve switch
date and time.
The director or switch
date and time cannot be
retrieved by the Element
Manager because the
Ethernet link is down or
busy.
Retry the operation later. If the
condition persists, contact the next
level of support.
Cannot retrieve switch
state.
The director or switch
state cannot be retrieved
by the Element Manager
because the Ethernet link
is down or busy.
Retry the operation later. If the
condition persists, contact the next
level of support.
Cannot run diagnostics
on a port that is failed.
Port diagnostics
(loopback tests) cannot
be performed on a port
that has failed any
previous diagnostic
(power-on diagnostic,
online diagnostic, or
loopback test). The amber
LED associated with the
port illuminates to
indicate the failed state.
Reset the port and perform
diagnostics again.
Cannot run diagnostics
on an active E-port.
Port diagnostics cannot
be performed on an
active E-port.
Run diagnostics on an E-port only
when it is not active.
Cannot run diagnostics
on a port that is not
installed.
Port diagnostics cannot
be performed on a port
card that is not installed.
Run diagnostics only on a port that
is installed.
Cannot run diagnostics
on a port card that is not
installed.
Port diagnostics
(loopback tests) cannot
be performed on a port
that does not have a
small form factor (SFF)
optical transceiver
installed.
Install a transceiver in the port and
perform diagnostics again.
Table 30 Element Manager messages (continued)
Message Description Action