FW 05.01.00 and SW 07.01.00 HP StorageWorks Embedded Web Server User Guide (AA-RTDRB-TE, June 2003)

Configuring the Product
50 Embedded Web Server User Guide
Note: For the Director 2/140, ports are displayed through several pages in groups of
32. To configure all of the ports, make sure you go through each set. You must click
Activate for each view before moving to the next.
To configure Open Trunking:
1. Choose Configure from the navigation panel.
2. Choose the Performance tab and the Open Trunking tab. The Open
Trunking tab view displays (Figure 16).
Figure 16: Configuring Open Trunking
3. Choose Enabled in the Open Trunking State drop down list.
4. Choose Enabled or Disabled from the Unresolved Congestion Event
Notification drop down list. If enabled, an unresolved congestion entry is
made in the event log and, if SNMP is configured, an SNMP trap is generated.
Unresolved congestion occurs when a flow cannot be rerouted to another link
because it would exceed the other link's threshold.