McDATA 4Gb SAN Switch for HP p-Class BladeSystem User Guide (AA-RW20B-TE, December 2005)

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 59
Creating a zone in a zone set
To create a zone in a zone set, perform the following procedure:
1. Select Zoning > Edit Zoning to open the Edit Zoning dialog.
2. Select a zone set in which to create a zone.
3. Select Edit > Create a Zone.
4. Enter a name for the new zone in the Create a Zone dialog
The new zone name is displayed in the Zone Sets dialog. A zone name must begin with a letter and be
no longer than 64 characters. Valid characters are 0—9, A—Z, a—z, _, ^, $, and -.
5. Click OK.
NOTE: If you enter the name of a zone that already exists in the database, the McDATA Web Server
application will ask if you would like to add that zone and its membership to the zone set.
6. To add switch ports or attached devices to the zone, choose one of the following:
Select the zone set In the zone set tree. Select the port to add to the zone in the graphic window.
Select Edit > Add Members.
Select a port by port number or World Wide Name in the Port/Device tree, and drag it into the
zone.
Select a port by port number or World Wide Name in the Port/Device tree. Right-click the zone.
Select Add Zone Members from the popup menu.
7. Click Apply to save changes to the zoning database.
Adding zone members
You can zone a port/device by switch domain ID and port number, or the device port WWN. Adding a
port/device to a zone affects every zone set in which that zone is a member. Domain ID/port zoning is
only supported in McDATA Fabric interop mode for other McDATA switches. To add ports/devices to a
zone, perform the following procedure:
1. Select Zoning > Edit Zoning to open the Edit Zoning dialog.
2. Choose one of the following methods to add the port/device:
Select a port/device in the Port/Device tree, and drag it into the zone. Press and hold Control while
selecting multiple ports/devices.
Select a port/device in the Port/Device tree. Press and hold Control while selecting to select multiple
ports/devices. Select a zone set in the left pane. Select Edit > Add Members.
Select a port/device in the Port/Device tree. Press and hold Control while selecting multiple
ports/devices. Select a zone set in the left pane. Click Insert.
If the port/device you want to add is not in the Port/Device tree, you can add it by doing the following:
a. Right-click the selected zone.
b. Select Edit > Create Members.
c. Select the WWN or Domain/Port option.
d. Enter the hexadecimal value for the port/device according to the option selection: 16 digits for a
WWN member, or 4 digits for a Domain/ Port member (DDPP). Domain IDs can be 97–127 when
interop mode is set to Standard or1–31 when interop mode is set to McDATA Fabric mode.
3. Click OK to add the member and save the change.
NOTE: Domain ID conflicts can result in automatic reassignment of switch domain IDs. These
reassignments are not reflected in zones that use domain ID/port number pair to define their membership.
Be sure to reconfigure zones that are affected by a domain ID change.