72 Managing switches
Interop Mode Interoperability mode. Use Standard to connect to FC-SW-2
compliant switches and McDATA switches in Open Fabric
Mode. Use McDATA Fabric Mode to connect to McDATA
switches in McDATA Fabric Mode. The default is Standard.
Legacy Address Format Not applicable
Interop Auto Save Zoning auto save status. Saves zoning updates in temporary
memory and the zoning database (True), or only in
temporary memory (False).
Zoning Default Visibility Not applicable.
Default Zone The Default Zone parameter enables (True) or disables
(False) communication among ports/devices that are not
defined in the active zone set or when there is no active
zone set.
Discard Inactive Not applicable.
Temperature Internal switch temperature °C
Security Auto Save If enabled (default), the security configuration is saved to
non-volatile memory on the switch. If disabled, the security
file is saved only to temporary memory. The Auto Save
feature is used when Fabric Binding is enabled. When Auto
Save is disabled, any updates from remote switches will not
be saved locally. If the local switch is reset, it may isolate.
Security Fabric Binding
Enable
If enabled, the expected domain ID of a switch is required
before attaching to the fabric
Fan 1 Status Not applicable
Fan 2 Status Not applicable
Power Supply 1 Status Power supply 1 status
Power Supply 2 Status Not applicable
Beacon Status Beacon status. Switch LEDs are blinking (on) or not (off).
Broadcast Support Broadcast support status. Broadcast support is enabled or
disabled (default).
In-band Enabled In-band management status. Permits (True) or prevents
(False) a switch from being managed over a FC port.
Temperature Failure Port
Shutdown
Non-configurable (always enabled for this switch). All ports
are downed when the switch temperature exceeds the
Failure Temperature.
Warning Temperature Non-configurable temperature threshold (65° Celsius) above
which a warning condition alarm is generated.
Failure Temperature Non-configurable temperature threshold (70° Celsius) above
which a failure condition alarm is generated.
NTP Client Enabled Enabled or disabled. Allows for switches to synchronize their
time a centralized server.
NTP Server Address The IP address of the centralized NTP server. Ethernet
connection to NTP server is required.
Table 9 Switch data window entries (continued)
Entry Description