FW 07.00.00/HAFM SW 08.06.00 McDATA E/OS SNMP Support Manual (620-000131-620, April 2005)

2
2-98
E/OS SNMP Support Manual
McDATA SNMP Support
Value http://switch’s IP-addr
Access R
Description The top-level URL of the system. If it does not exist the value is an
empty string. The URL format is implementation dependent and can
have keywords embedded that are preceded by a percent sign
(e.g.,%USER).
The following are the defined keywords that will be recognized and
replaced with data during a launch:
USER replace with username
PASSWORD replace with password
GLOBALID replace with globalid
SERIALNO replace with serial number
A management application will read this object from the MIB,
provide values for any of the keywords listed above that are present
in the string, and then use the URL to invoke or launch the program
referenced.
FcConnUnitSnsMaxRows
Type Unsigned32 (Same as Gauge).
Value The number of the entries of the Name Server Table.
Access R
Description The maximum number of rows in the fcConnUnitSnsTable table.
fcConnUnitTable Contains general information on the system’s units
*fcConnUnitId
Type OCTET STRING
Product Mapping Switch’s WWN.
Access R
Description The unique identification for this connectivity unit among those
within this proxy domain. The value MUST be unique within the
proxy domain because it is the index variable for
fcConnUnitTable.