FW 07.00.00/HAFM SW 08.06.00 McDATA E/OS SNMP Support Manual (620-000131-620, April 2005)

A
FA MIB
A-13
Fibre Alliance MIB
Max-Access read-only
Status current
Description 24 bit Fibre Channel address ID of this connectivity unit. Following
the fibre channel standard, the right-most bit of the right-most octet is
for the least significant bit of the address value; the left-most bit of the
left-most octet, if needed, is for the most significant bit of the address
value. If this value is not applicable, all bits set to 1.
Sequence
::= { fcConnUnitEntry 11 }
fcConnUnitProxyMaster
Syntax INTEGER { unknown(1), no(2), yes(3) }
Max-Access read-only
Status current
Description A value of 'yes' means this is the proxy master unit for a set of
managed units. For example, this could be the only unit with a
management card in it for a set of units. A standalone unit should
return 'yes' for this object.
Sequence
::= { fcConnUnitEntry 12 }
fcConnUnitPrincipal
Syntax INTEGER {unknown(1), no(2), yes(3) }
Max-Access read-only
Status current
Description Whether this connectivity unit is the principal unit within the group
of fabric elements. If this value is not applicable, return unknown.
Sequence
::= { fcConnUnitEntry 13 }
fcConnUnitNumSensors
Syntax Unsigned32
Max-Access read-only
Status current
Description Number of sensors in the fcConnUnitSensorTable.