FW 07.00.00/HAFM SW 08.06.00 McDATA E/OS SNMP Support Manual (620-000131-620, April 2005)

B
B-54
E/OS SNMP Support Manual
FC Management MIB
Description A count of the errors that have occurred on this port.
Sequence
::= { connUnitPortStatEntry 3 }
connUnitPortStatCountTxObjects
Syntax OCTET STRING (SIZE (8))
Access read-only
Status mandatory
Description The number of frames/packets/IOs/etc. that have been transmitted
by this port. Note: A Fibre Channel frame starts with SOF and ends
with EOF. FC loop devices should not count frames passed through.
This value represents the sum total for all other Tx objects.
Sequence
::= { connUnitPortStatEntry 4 }
connUnitPortStatCountRxObjects
Syntax OCTET STRING (SIZE (8))
Access read-only
Status mandatory
Description The number of frames/packets/IOs/etc. that have been received by
this port. Note: A Fibre Channel frame starts with SOF and ends with
EOF. FC loop devices should not count frames passed through. This
value represents the sum total for all other Rx objects.
Sequence
::= { connUnitPortStatEntry 5 }
connUnitPortStatCountTxElements
Syntax OCTET STRING (SIZE (8))
Access read-only
Status mandatory
Description The number of octets or bytes that have been transmitted by this port.
One second periodic polling of the port. This value is saved and
compared with the next polled value to compute net throughput.
Note, for Fibre Channel, ordered sets are not included in the count.
Sequence
::= { connUnitPortStatEntry 6 }