McDATA 4Gb SAN Switch for HP p-Class BladeSystem User Guide (AA-RW20B-TE, December 2005)

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 71
Switch data window
The Switch data window displays current network and switch information for the selected switches. See
Configuring a switch” on page 78 for more information about the Switch data window. Table 9 describes
the Switch data window entries.
To open the Switch data window, choose one of the following:
Select one or more switches in the topology display. Click the Switch data window tab.
Open the faceplate display. Click the Switch data window tab.
Table 9 Switch data window entries
Entry Description
First Port Address Switch FC address
World Wide Name Switch World Wide Name
Serial Number Number assigned to each chassis (required for PFE keys)
Reason for Status Additional status information
User Name Account name
Login Level Authority level
Super User Super user privileges enabled/disabled
UserAuthentication Enabled Enforcement of account names and authority (always True)
Vendor Switch manufacturer
Firmware Version Active firmware version
Inactive Firmware Version Not applicable
Pending Firmware Version Firmware version that will be activated at the next reset
PROM/Boot Version PROM boot version
MAC Address Media Access Control address
IP Address Internet Protocol address
Subnet Mask Mask that determines the IP address subnet
Gateway Gateway address
SNMP Enabled SNMP enabled or disabled
Negotiated Domain ID The domain ID currently being used by the fabric
Configured Domain ID The domain ID defined by network administrator
Domain ID Lock Domain ID lock status. Prevents (True) or permits
(False—Default) dynamic domain ID reassignment
Number of Ports Number of ports activated on the switch
Operational State Switch operational state: online, offline, diagnostic, down
Administrative State Current switch administrative state
Configured Admin State Switch administrative state that is stored in the switch
configuration
R_A_TOV Resource allocation timeout value
E_D_TOV Error detect timeout value