Fixes
Table 2 lists issues that hav e been xed in HAFM 08.09.01 since the release of HAFM 08.08.00.
Table 2 HAFM 0
8.09.01 xes
Description
Problem Category
The Operational Status column does not update correctly when a
McDATA 4Gb SAN Switch is taken ofine. Instead of indicating
that the McDATA 4G b SAN Switch is ofine, the status in the
OperationStatuscolumnandalerticon(ProductListandTopology
view)displaysasfailed.
Display/Layout/GUI
Topology view has update problems when the principle switch is
not mana ged by HAFM and the fabric is segmented. The device
list adjacent to the topology may display the same switch in two
different fabrics or the switch may toggle from one fabric to another,
at a rate of approxi mately half of the d i scovery rate (approxima
tely
eight seconds).
Display/Layout/GUI
In the product List, Domain ID column not getting sorted properly.
Device List/Properties
Unable to discover switch when IP is reused in a switch swap-out
scenario.
Discovery
Changing the server time back causes the link to drop or the clos
es
the Element Manager. When the user attempts to reopen Elemen
t
Manager, the following message appears: The link to the
product is not available: Connection lost.
Element Manager
A Preferred Pa th cannot be enabled intermittently even when the
Domain ID is set to Insistent.
Element Manager
With FI CO N Managem e nt st yle, the Ad dresses menu item under
the Congure menu (Configure > Addresses)isnotavailable
in the 6140 E lement Manager.
Element Manager
When performing a CTP switch over from either CTP 0 or 1, the entire
Hardware View window is blank until stopping and starting services.
Element Manager
The user is not notied that rmware download on single-CTP system
causes switch to boot the IPL le rather tha n the current active
conguration.
Element Manager
For an upgrade rmware install, the red progress bar is not updated.
Element Manager
Stopping External port diagnostics in the middle of a t
est may cause
port to indicate failure.
Element Manager
Firmware may not update on HP-UX systems. Element Manager
The cooling fan mod u le may display incorrect position in formation
in the element manager FRU list.
Element Manager
Port status alert indicator may not be removed when a NOS alert
is cleared from Por ts tab
Element Manager
No log entries generated when a link between switches is
disconnected.
Event Manag em ent
User Action Event may not be generated in Master log for
modications done in Call Home d ialog.
Event Notication
The HAFM Event Log is missing system power up and st
andby ready
events after system power down.
Element Manager
When enabling or disabling fabric binding on muliple fabrics, th e
wrong WW N displays in the Fabric Name eld of the Fabric Binding
Status window.
Fabric Binding
HA-Fabric Manager release notes
5