High Availability Monitors Version A.03.00.01 Release Notes

Chapter 1 9
High Availability Monitors Version A.03.00.01 Release Notes
Compatibility Information and Installation Requirements
Download the latest templates from the http://software.hp.com web site.
Click High Availability, then Event Monitoring Service Depelopers’ Kit.
The templates are in a list near the bottom of the Developers’ Kit page.
Requirements for Disk Monitor Users:
There are two cases where the Disk Monitor has software requirements:
NIO Bus: To use the Disk Monitor with disks connected by an NIO
bus, you must configure the SCSI pass-thru driver, spt0, into the
kernel.
For HP-UX 10.20, install patch PHKL_13044 to add SCSI
pass-thru driver support. Add spt0 to the /stand/system file,
rebuild the kernel, and reboot.
For HP-UX 11.0, add spt0 to the /stand/system file, rebuild the
kernel, and reboot. (The SCSI passthru driver is already part of
the 11.0 operating system.)
Fibre Channel: To use the Disk Monitor with disks connected by fibre
channel, you must already have the SCSI passthru driver installed,
as described in NIO Bus, above. Then, follow the directions below:
For HP-UX 10.20, install Fibre Channel Mass Storage Driver
product J3630BA, and any recommended patches.
For HP-UX 11.0, install patch PHSS_14652, or the patch that
supersedes it, to get the latest fibre channel driver.
You may see a NOTE in your swinstall log if you do not have spt0 as
part of your kernel. The note is information only, and does not mean that
there is a problem in the installation.
Hardware Requirements
HA Monitors run on the HP 9000 series 800 servers.
The disk monitor supports SCSI SE (single-ended) and F/W (fast/wide)
disks, including:
Hewlett-Packard High Availability Disk Array, Models 10 and 20
Hewlett-Packard Disk Array with AutoRAID, Models 12 and 12H
EMC Symmetrix arrays for both fibre channel and SCSI disks
Hewlett-Packard High Availability Storage System