FW 07.00.00/HAFM SW 08.06.00 McDATA SANpilot User Manual (620-000160-230, April 2005)

3
MAP 0400: Loss of Console Communication
3-59
Diagnostics
Bits per second - 57600.
Data bits - 8.
Parity - None.
Stop bits - 1.
Flow control - Hardware.
When the parameters are set, click OK. The HyperTerminal
window displays.
i. At the > prompt, type the user-level password (the default is
password) and press Enter. The password is case sensitive.
The HyperTerminal window displays with software and hardware
version information for the switch, and an C> prompt at the
bottom of the window.
j. At the C> prompt, type the ipconfig command and press Enter.
The HyperTerminal window displays with configuration
information listed (including the IP address).
Figure 3-25 Hyperterminal Window - Configuration Information
k. Record the switch IP address.
l. Select Exit from the File pull-down menu to close the
HyperTerminal application. The following message box appears: