FW 07.00.00/HAFM SW 08.06.00 McDATA SANpilot User Manual (620-000160-230, April 2005)

A
A-8
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
Messages
Action Run diagnostics on an E-port only when it is not active.
Message Cannot run diagnostics while a device is logged-in to the port.
Description A device is logged in to the port where a diagnostic test is attempted.
Action Log out the device and run the diagnostic test again.
Message Cannot run diagnostics. The port is not installed.
Description Port diagnostics cannot be performed when the port is not installed.
Action Run diagnostics only on a port that is installed.
Message Cannot save IPL configuration file while active=saved is enabled.
Description The user cannot save the IPL file while the active=save property is
set.
Action The FICON management server property, active=save, must be
disabled for EFCM to save the IPL file.
Message Cannot save port configuration.
Description Port configuration cannot be saved. The link is down or busy.
Action Retry the operation later. If the condition persists, contact support
personnel.
Message Cannot save SNMP configuration.
Description SNMP configuration cannot be saved. The link is down or busy.
Action Retry the operation later. If the condition persists, contact support
personnel.