FW 07.00.00/HAFM SW 08.06.00 McDATA SANpilot User Manual (620-000160-230, April 2005)

B
System Events (000 through 199)
B-11
Event Code Tables
Event Code: 072
Message: E_Port connected to unsupported switch
Severity: Informational
Explanation: The device connected to the other end of the interswitch link is not compatible.
Action: Disconnect the interswitch link.
Event Data: No supplementary data included with this event.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔
Event Code: 073
Message: Fabric Init Error
Severity: Informational
Explanation: There was an error detected in the fabric initialization sequence. Most problems are caused by frame delivery
errors. The Event data is intended for engineering evaluation of the problem. It includes a reason code and if
applicable, a list of ports that problems were detected over.
Action: Perform a data collection operation and contact a service representative.
Event Data: Byte 0: The error Reason Code.
01 = Error no notification for principal switch. Not principal switch and never receives AAI (DIA) from
the principal switch
02 = Error domain ID not assigned. Not principal switch and got no response to RDI. Unable to
allocate a domain ID.
03 = Fabric initializion completed and discover neighbor switches not in local domain ID list. After the
fabric init sequence completes, directly connected switches are not included in the local domain
id list..
04-FF = Reserved.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔