FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks HA-Fabric Manager Release Notes (AA-RUR6F-TE/958-000288-010, August 2005)

NOTE:
HAFM is not required for operating hardware products using the rmware.
All directors and edge switches in the same fabric should have the same rmware level
installed. Althoug h products m ay coexist in a fabric running different levels of rmware,
all products must be at the same m ajor functional release level.
HAFM upgrade required for rmwar e version 07.xx.xx
To upgrade to rmware 0 7.00.00-84, you must rst upgrade the HAFM software to
07.01.00-9 minimum, if you are using the notebook HAFM server to manage the
director or edge switch. The HAFM software is contained on the HP StorageWorks
ha-fabric manager documentation and software CD (Part Number 516-000024-820) .
An upgrade kit to HAFM 07.01.00-9 is also available, Part Num b er 320908-B22, for
owners of license for previous versions. This HA FM upgrade is also available on the
following HP web site: h
ttp://h18006.www1.hp.com/storage/saninfrastructure.html
If you are using the 1U rack-mount HAFM appliance to manage the director or edge
switch, the minimum HA FM version required is 07.02.00-9, which is the minimum version
installed. Th is HAFM software is contained on the HP StorageWorks ha-fabric man ager
documentation and software CD (Part Number 516-000024-720) .
The previous minimum versions of HAFM allow you to m anage directors or edge
switches running 07.00.00-84 rmware, but to be able to use a ll the new features and
enhancements, you need to upgrade HAFM to 08.06.00, which runs only on the 1U
rack-mount HAFM appliance.
As an alternative, you can perform the rmware upgrade directly to the d irector or edge
switch using their EWS.
Please contact your local HP technical resource if you need to obtain a new HAFM
version.
Please contact your local HP technical resource to conrm compatibility with devices
in your SAN before upgrading to this rmware version.
For more information on upgrading software versions, refer to the HP StorageWorks
HA-Fabric M anager User Guide. The features of this software version are detailed in the
accompanying manuals listed in section Other HAFM do cumentation.
Upgradingfromanearlierversionofrmw ar e
Upgrading to rmware 07.00.00-84 is non-disruptive to attached dev ices. The director
or edge switch is not required to be ofinebeforeperforminganupgradeoperation.
Limitations to upgrades are clearly identied if there are a ny limitations to performing
the operation.
Before upgrading rmware, it is highly recommended that you back up the director or
edge switch conguration. Refer to your HP StorageWorks director or edge switch