FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks HA-Fabric Manager Release Notes (AA-RUR6F-TE/958-000288-010, August 2005)

Element M anager user guide for more information. Embedded Web Server (EWS)
also provides an option to print or save product conguration to a le. Refer to the
HP StorageWorks Embedded We b Server User Guide for more information.
All products must b e running rmware 06.00.00 or later b efore upgrading to
07.00.00-84. If a switch is operating with a rmware level earlier than 06.00.00, you
must upgrade to 06.xx.xx before installing 07.00.00-84.
Upgrades and downgrades are supported only from one major release to the next, such
as from 06.xx.xx to 07.00.00-84. If EWS is used for upgrades and downgrades, and
this rule is not followed, errors o ccur and there m ay be a disruption to attached devices.
If upgrading to rmware 06.02 .00-22 requires you to upgrade from 04.xx.xx to
05.xx.xx in the process, there are special considerations:
For directors, refer to Upgrading rmware on a director from 04.xx.xx to
05.xx.xx
For edge switches, refer to Upgrading rmware on an edge switch from 04.xx.xx
to 05.xx.xx
A s ma ll number of early-shipped Surestore Director FC-64 units may receive one of the
following messages when they upgrade to rmware 05.02.00-13:
HAFM—Firmware cannot be loaded due to insufcient CTP memory.
EWS—File System E rror: Insufcient m em ory for new rmware version.
This occurs only in cer tain units with CTP cards. Units with CTP2 cards do not have
this issue.
If you get one of these messages during the upgrade, the rmware upgrade failed, but
the unit continues working with the existing rmware without a n interruption in service.
The upgrade process checks for sufcient memory before activating the new rmware
image. The rmware upgrade does not complete without sufcient m emory. Please
contact HP Customer Support if you receive this message.
Some customer environments use application or host software that is affected by the
restart of the director CTP during a HotCAT download operation. Applications that rely
on inband management servers are especially prone to problems caused by processor
restart. For example, an application may be congured to poll the director or switch
at regular intervals. The polling process could occur d uring a restart period, causing
the application software to react adversely. As a solution, shut d own those applications
driving inband requests during a rmware upgrade, then restar t the applications after
upgrade completion.
Upg
rading rmware on an edge switch from 04.xx.xx to 05.xx.xx
An i
ssue has been identied in release 04.xx.xx if the contents of the nonvolatile storage
(NV
RAM) on the CTP become corrupted. Once the conguration has been loaded,
th
is corruption is not detected until an IPL/IML, power cycle, or rmware code load.
If the N VRAM in the CTP has corrupted contents, the rmware load can cause the
conguration to reset to factory defaults, which could cause a system outage.
HP StorageWorks HA-Fabric Mana g er release notes
9