FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks HA-Fabric Manager Release Notes (AA-RUR6F-TE/958-000288-010, August 2005)

For procedures to download rmware to the switch or director using the H A F M Element
Manager interface or EWS interface, refer to the following:
The switch or director Installation and Service Manual. This publication
provides complete procedures for obtaining rmware from the HP web site and
downloading rmware to the switch or d irector using HAFM.
The switch or director Element Manager online help and User Manual. These
includes instructions for downloading rmware to the switch or director using the
HAFM inter face.
EWS User Manual. This provides procedures for downloading rmware to the
switch or director.
EWS online help. This provides procedures for downloading rmwar e to the
switch or director.
Downgrading directly to a release before 06.00.00 from 07.00.00-84 is not allowed.
To downgrade to a release before 06.00.00, you must rst downgrade to 06.YY.ZZ.
Upgrades and downgrades are supported only from one major release to the next, such
as from 06.xx.xx to 07.00.00-84. If EWS is used for upgrades and downgrades, and
this rule is not followed, errors occur and there may be a disruption to attached devices.
Downgrading to release 6.0 with the Preferred Path feature con gured could cause loss
of this function. HP recommends that Preferred Path be disabled before downgrading.
To do this, d eselect the check box for Enab l e Preferred Path in the Congure Preferred
Paths dialog box.
NOTE:
The D irector 2/140 and the Edge Switch 2/24 cannot be downgraded earlier than
04.01.00, and the Edge Switch 2/12 cannot be downgraded earlier than 05.05.00.
If a Director 2/140 in a multiswitch fabric is downgraded earlier than 06.02.00, ISLs
could become segmented if there are any other switches in the fabric operating with a
rmware version earlier than 06.01.00. To prevent this situation, downgrade all Director
2/140s in the fabric to 06.01.00 b efore downgrading any products in the fabric to
05.xx.xx. This problem only exists with Director 2/140s in the fabric. HAFM displays a
warning message if a downgrade from 06.02.00 is attempted, but you c an continue
with the downgrade if desired.
NOTE:
The warning message is displayed when downgrading any model from 06.02.00, but
only applies to downgrade op erations for the Director 2/140.
Downgrades directly to 05.03.01 from 06.xx.xx is not concurrent when the
second-generation Edge Switch 2 /24 is congured in Open Fabric operating
m
ode. In other words, downgrades in Open Fabric modecannotbedonewiththe
s
econd-generation Edge Switch 2/24 online without d isrupting port operations. Since
12