FW 07.00.00/HAFM SW 08.06.00 HP StorageWorks HA-Fabric Manager Release Notes (AA-RUR6F-TE/958-000288-010, August 2005)

managed via either L AN, the public LAN is the only one that can suppor t remote client
access. Thus, if one a ttempts to access the HAFM appliance via a remote client session
and is unknowingly using what has been designated as the private LAN, the remote
session is not allowed. The IP address that the HAFM appliance has determined to be
thepublicLANwhichsupportsremoteclientaccess,displaysHAFMwhichdisplays
after selecting SAN > Server Properties.
HAFM designates the public LAN as the rst LAN detected whose IP address is n ot the
reserved private subnet 10.x.x.x. Thus, if neither IP address is 10.x.x.x,therst
L AN detected by HAFM is designated as the public LAN. This order of d etection is
inuenced by Microsoft Windows and is not guaranteed.
For a dual LAN conguration, both LANs must be connected when the HAFM
appliance is b ooted up. If only one is connected, HA FM interprets this as a single
LAN conguration, and the connected LAN is designated as the L AN for remote client
sessions.
Workaround
There are a two ways to ensure the pubic and private designations of the LANs.
If you use a
private LAN IP address, this causes this LAN to be designated as
the private LAN. You must also have the public L A N connection active when the
HAFM appliance is booting up, or else HAFM interprets this as a single LAN
connection cong uration, and the 10.x.x.x LAN is designated as the LAN for
remote cl
ient sessions.
You can congure a specied Ethernet interface on the HAFM appliance to be
the public LAN (to listen for remote client connections). To congure this feature,
you must manually edit a le on the HAFM appliance to explicitly specify which
IP address HAFM should use as the public LAN.
For det
ailed instructions, see HP StorageWorks HA-Fabric Ma nager User Guide.
If the p
ublic LAN IP address of the HAFM appliance is ever changed, this le
must b
eeditedagaintoreect the new IP address.
Known issues
This section describes the known issues related to the 1U HA FM appliance a nd the
HAFM software.
Sett
ing date/time of HAFM appliance to earlier time may cause loss of
mana
gement to switches
When changing the HAFM appliance time to an earlier time, the Ethernet link to
directors and e d ge switches may be lost, or an open element manager may close.
When
attempting to reopen the element manager, the error message “The link to the
product is not available: Connection lost may be displayed.
22