Diagnostics
.
Figure 3-5 Link Incident Log
If a link incident occurred, the affected port number is listed with one
of the following messages.
Link interface incident - implicit incident.
Link interface incident - bit-error threshold exceeded.
Link failure - loss of signal or loss of synchronization.
Link failure - not-operational primitive sequence (NOS)
received.
Link failure - primitive sequence timeout.
Link failure - invalid primitive sequence received for the
current link state.
Did one of the listed messages appear in the Link Incident Log?
YES NO
The switch appears operational.
A link incident problem is indicated. Go to step 23 to obtain event
codes. If no event codes are found, go to MAP 0600: Port Failure and
Link Incident Analysis on page 3-72.