HP StorageWorks HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server 2003 (32-bit) Release Notes (AA-RV1YA-TE, March 2005)

ACS Enhancements and Fixes
17HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for
Windows NT, Windows 2000, and Windows Server 2003 (32-bit) Release Notes
11. REINITIALIZE container-name
SPECIAL_FUNCTION_ONE=
NOPARTITION
Directs the controller to reset the partition
flag bits on devices in a container and
establishes the container as a
non-partitioned container. This command
can only be used with RAIDset containers.
Caution: Ensure that the container
was previously initiated as a
non-partitioned container before
using this command. Failure to do
so results in loss of access to any
partitioned data.
Note: Issuing the SPECIAL_
FUNCTION_ONE=PARTITION or the
SPECIAL_FUNCTION_ONE=
NOPARTITION switch in dual-redundant
controller configurations causes the
container ownership to move to the
controller from which the REINITIALIZE
container-name
command was
not
issued.
12. SHOW RAIDSETS
SPECIAL_FUNCTION_ONE
Displays a listing of all RAIDset containers
and either one of three possible container
statuses: Good, Maintenance
Recommended, or REPORTED ON THE
OTHER CONTROLLER.
Note: Refer to Chapter 4 of the
HP
StorageWorks HSG60 and HSG80 Array
Controller and Array Controller Software
Maintenance and Service Guide
for
additional details related to this command.
Table 1: New CLI Commands and Switches (Continued)
Item CLI Command or Switch Description and Background