HP Comware 5 Debug Manual Vol 1

[Sysname] bfd min-receive-interval 500
*0.6557156 Sysname BFD/8/ERR: Failed to create interface: ethernet1/1
// BFD failed to create the interface.
debugging bfd event
Use debugging bfd event to enable BFD event debugging.
Use undo debugging bfd event to disable BFD event debugging.
Syntax
debugging bfd event
undo debugging bfd event
Default
BFD event debugging is disabled.
Views
User view
Default command level
1: Monitor level
Usage guidelines
Table 89 describes output fields and messages for the debugging bfd event command.
Table 89 Output from the debugging bfd event command
Field
Description
Sync if: Failed to encode IPC message. Len(message
length)
The active MPU failed to encapsulate the IPC message
before sending interface structure.
Send interface message to (chassis chassis-id, slot
slot-id)
The active MPU sent the IPC message containing
interface structure to the newly inserted interface card
(interface card number).
Sync if: Failed to encode last IPC message.
Len(message length)
During interface information synchronization, the
active MPU failed to encapsulate the last IPC
message.
Send last interface message to (chassis chassis-id, slot
slot-id)
The active MPU sent the last IPC message containing
interface structure to the newly inserted interface card
(interface card number).
Sync sess: Failed to encode last IPC message.
Len(message length)
During session information synchronization, the active
MPU failed to encapsulate the last IPC message.
Process sync if: Failed to create interface
(Interface Index)
The newly inserted interface card failed to create the
interface after receiving the IPC message with
interface structure from the active MPU.
Process sync if: Error, interface(Interface Index) exist
When the newly inserted interface card used the IPC
message with interface structure received from the
active MPU to create the interface, an error occurred
due to the existence of the interface.
166