HP Comware 5 Debug Manual Vol 1

Field
Description
DPL_INTF: [GetCallInfoTab]Cannot get CallInfoTab!
Perhaps, the table have been use up!
The call information table was unavailable. It was
possible that the table had been used up.
DPL_INTF: [UpdateEntityInfoForCall]Update failed!
Cannot find the entity 100!
Updating failed, and voice entity 100 was not found.
DPL_INTF: [GetNextEntityForCall]Entity 100 update
failed! The other process will be continued!
Updating voice entity 100 failed, and the other
processing continued.
Table 201 describes output fields and messages for the debugging voice dpl general command.
Table 201 Output from the debugging voice dpl general command
Field
Description
DPL_INTF: Get entity 100 successfully!
The dial plan module succeeded in obtaining voice
entity 100.
DPL_SRCH: [GetEntity]Found access service number is
301
The found access service number was 301.
DPL_INTF: [UpdateEntityInfoForCall]The current
connect number is 0. Perhaps, the configuration of
entity 100 have been modified.
The number of current connections was 0, and the
configuration of voice entity 100 might have been
modified.
DPL_INTF: [UpdateEntityInfoForCall]The current
connect number of the group is 0. Perhaps, the
configuration of max-con group have been modified.
Entity is 100.
The number of current connections of voice entity 100
in the set was 0, and the configuration of the
maximum-call-connection set might have been
modified.
DPL_SUBST: [MultTabMainProc]Found suitable
substitute rule:
szInputFormat: ^010100$ >> szOutputFormat:
100
Input Number Type: any(0x05) >> Output Number
Type: international(0x01)
Input Numbering Plan: any(0x05) >> Output
Numbering Plan: telex(0x04)
The following global number substitution rule was
found:
Input number: 01010 0.
Input number type: Any.
Input numbering plan: Any.
Output number: 100.
Output number type: International.
Output numbering plan: Telex.
DPL_SUBST: [MultTabMainProc]The user number has
been substituted successfully.
Original Number is 010100, Substituted Number
is 100;
Original Number Type is unknown(0x00),
Substituted Number Type is international(0x01);
Original Numbering Plan is unknown(0x00),
Substituted Numbering Plan is telex(0x04).
The global number substitution succeeded:
Input number: 01010 0.
Input number type: Unknown.
Input numbering plan: Unknown.
Output number: 100.
Output number type: International.
Output numbering plan: Telex.
380