HP Comware 5 Debug Manual Vol 1

Field
Description
NOT Resetting the send position
The sending position was not reset although the replied
serial number was wrong.
Received seqnum seq-number, expected
exp-number dropping...
The standby MPU discarded the packet because the
serial number was wrong.
WARNING: IPC Queue is Full, Will be Resent Later
size:%d MID=%x SID=%x
The IPC queue was full when HA was sending a
message.
Event Write Failed ..... Failed to write events to the HA module.
Error in Creating HA Timer HA failed to create a timer.
Error in Deleting HA Timer HA failed to delete the timer.
HA_Send Message: IPC Allocation Failed.... HA failed to allocate memory when sending a message.
IPC Send Failed because IPC Queue is FULL
HA failed to send a message because the IPC queue was
full.
HA Send ACK: IPC Alloc Failed...
HA failed to allocate memory when sending an
acknowledgement.
HA Can't allocate memory HA failed to allocate memory.
IPC Create Failed for HA.... HA failed to create an IPC tunnel.
Register to IPC for Status Notification Failed.... HA failed to register with IPC.
HA Receives Unknown Message type from IPC... HA received a message with unknown type from IPC.
Unknown Status message from IPC .. HA received a message with unknown state from IPC.
HA Send Message: IPC Alloc Failed... HA failed to allocate memory when sending a message.
ERROR:Send Message is NULL.
HA failed to send a message because the queue was
empty.
IPC Send Failed because Bad parameter IPC message sending failed because of parameter error.
Table 25 describes output fields and messages for the debugging ha event command.
Table 25 Output from the debugging ha event command
Field
Description
%d:%d:%d %d/%d/%d
HA: Notify module %lx.%lx to batch backup at %s.
HA notified each module when it bulk backed up
data.
%d:%d:%d %d/%d/%d
Notify module %lx.%lx to smooth at %s.
HA notified each module when it performed data
smoothing.
Table 26 describes output fields and messages for the debugging ha message command.
71