R3303-HP HSR6800 Routers Interface Command Reference

Table Of Contents
21
Use undo flow-interval to restore the default interval.
Syntax
flow-interval interval
undo flow-interval
Default
The interface statistics polling interval is 300 seconds.
Views
System view
Default command level
2: System level
Parameters
interval: Sets the statistics polling interval, in seconds. It is in the range of 5 to 300 and must be a multiple
of 5.
Usage guidelines
A device supports the global configuration mode. In system view, use the flow-interval command to set
the statistics polling interval for all interfaces.
Examples
# Set the statistics polling interval to 100 seconds for all Ethernet interfaces.
<Sysname> system-view
[Sysname] flow-interval 100
interface
Use interface to enter interface or subinterface view. If you specify the interface-number.subnumber
argument and the subinterface does not exist, this command creates first the subinterface, and then
enters subinterface view.
Syntax
interface interface-type { interface-number | interface-number.subnumber }
Views
System view
Default command level
2: System level
Parameters
interface-type: Specifies an interface type.
interface-number: Specifies an interface number.
interface-number.subnumber: Specifies a subinterface number, where interface-number is an interface
number, and subnumber is the number of a subinterface created under the interface. The subnumber
argument is in the range of 1 to 4094.