R3303-HP HSR6800 Routers Security Command Reference

85
Views
RADIUS scheme view
Default command level
2: System level
Parameters
minutes: Server quiet period in minutes, ranging from 0 to 255. If you set this argument to 0, when the
device attempts to send an authentication or accounting request but the current server is unreachable, the
device sends the request to the next server in active state, without changing the current server's status. As
a result, when the device attempts to send a request of the same type for another user, it still tries to send
the request to the current server because the current server is in active state.
Usage guidelines
The quiet timer controls whether the device changes the status of an unreachable server from active to
blocked and how long the device keeps an unreachable server in blocked state.
If you determine that the primary server is unreachable because the device's port connected to the server
is out of service temporarily or the server is busy, you can set the server quiet period to 0 so that the
device uses the primary server whenever possible.
Be sure to set the server quiet timer properly. Too short a quiet timer may result in frequent authentication
or accounting failures because the device keeps trying to communicate with an unreachable server that
is in active state.
Examples
# Set the quiet timer for the servers to 10 minutes.
<Sysname> system-view
[Sysname] radius scheme radius1
[Sysname-radius-radius1] timer quiet 10
Related commands
display radius scheme
timer realtime-accounting (RADIUS scheme view)
Use timer realtime-accounting to set the real-time accounting interval.
Use undo timer realtime-accounting to restore the default.
Syntax
timer realtime-accounting minutes
undo timer realtime-accounting
Default
The real-time accounting interval is 12 minutes.
Views
RADIUS scheme view
Default command level