on the determined size. The EFI code calculates the wrong size, hence the allocated buffer is too
small to hold the file.
Apart from updating the firmware, using a tftp server that supports the tsize option will also solve
this problem. The tsize option allows a tftp client to ask the tftp server for the size of the file. This
saves the client from having to download the file to determine its size.
The HP-UX 11i v2 operating system supports the tsize option from first release; HP-UX 11i v1
requires the patch PHNE_32825.
Using a tftp server that supports the tsizeoption makes network booting faster, since every file
to be downloaded from the Ignite server via tftp does not have to be downloaded twice (once to
determine its size, and again to download it into memory.)
File Size Miscalculated on HP Integrity Virtual Machines
AUTOBOOTING...Obtaining size of Rel_B.11.23/IINSTALL (63450640 bytes)
Downloading file Rel_B.11.23/IINSTALL /
TFTP session failed. (reason:Buffer Too Small)
Could not open Rel_B.11.23/IINSTALL
The error TFTP session failed. (reason:Buffer Too Small) is applicable only to HP
Integrity Virtual Machines. The reason is the same as described under the heading: File Size
Miscalculated. No version of HP Integrity VM contains fixed firmware at this time. To resolve this
issue, install the patches listed in the File Size Miscalculated section so the tftpd daemon supports
the tsize option.
Creation of Archive
Devices that do not support SCSI mode page 0x80 or 0x83 are not recovered correctly.
The system with OE versions earlier than March 2014, must have Ignite-UX version C.7.17.361
1
and the patches PHKL_43607 and PHCO_43594 installed. The attribute enable_get_config
must be set to ‘true’. These patches are required by Ignite-UX to create the archive correctly. If
these patches are not installed, then there may be issues during recovery of some of the devices,
which do not support SCSI INQUIRY pages (page 0x80 and page 0x83) used for uniquely
identifying these devices.
The attribute enable_get_config allows the serial number to be recorded for the device and
persistence to be maintained after recovery of some devices (for example, SATA DVD drives). Run
\"scsimgr save_attr -a enable_get_config=true\" to set the attribute to true.
Some of the USB DVD drives have been found not to return a valid serial number. Hence, on
systems that have Ignite-UX version C.7.17.361
2
and the patches PHKL_43607 and PHCO_43594
installed, with the attribute enable_get_config set to true, it is recommended to not connect
more than 1 USB DVD drive. In case you need to connect more than 1 USB DVD drive, it is
recommended to disable the fix by runningscsimgr save_attr a
enable_get_config=false, before connecting the additional USB DVD drive. For more
information about the patch and the attribute, see the patch documentation and scsimgr(1m)
manpage.
1. October 2013 Web release (C.7.17.361) is suspended and unsupported. See HP customer advisory c04008140 for
additional details.
2. October 2013 Web release (C.7.17.361) is suspended and unsupported. See HP customer advisory c04008140 for
additional details.
232 Troubleshooting