HP Intelligent Management Center v5.2 Branch Intelligent Management System User Guide

Set mail notification
The mail notification function enables the system to inform the maintainer of alarms (including the
CPE name, alarm name, alarm level, alarm time, and alarm cause) by sending mails.
NOTE: To add a mail notification, make sure that the mail server is configured properly.
1. Click the Alarm tab, and then in the CPE Alarm navigation tree click Alarm Notification to
display the alarm notification page.
2. The mail notification list provides the following operations:
Click Add to display the Add Mail Notification page.
Click the Configure Mail Server link to display the Mail Server Settings page.
Click the status link to change the status (Enabled/Disabled) of the mail notification.
Click to display the Modify Mail Notification page.
Click to display the Copy Mail Notification page.
Click to delete the mail notification.
Click Refresh to refresh the mail notification list.
3. Select Add, Modify, or Copy mail notification.
Add/Modify mail notification
The mail notification function enables the system to inform the maintainer of alarms (including the
CPE name, alarm name, alarm level, alarm time, and alarm cause) by sending mails.
NOTE: To add a mail notification, make sure that the mail server is configured properly.
1. Click the Alarm tab, and then in the CPE Alarm navigation tree click Alarm Notification to
display the alarm notification page.
2. Click Add above the mail notification list to enter the page for adding a mail notification rule,
or click of a mail notification rule to enter the page for modifying the mail notification rule.
3. Enter a rule name (for adding a mail notification rule).
NOTE: In a mail notification rule, the logical relationship among the conditions is AND.
4. Enter the destination mail address.
5. Select the appropriate alarm levels.
NOTE: If you select All Alarms, all types of alarms are forwarded. If you select Selected
Alarms, only the selected alarms are forwarded.
6. Select the applicable CPEs.
NOTE: If you select All CPEs, alarms of all the CPEs are forwarded. If you select Selected
CPEs, only the alarms of the selected CPEs are forwarded.
7. Select the applicable alarms.
8. Enter the time range on each day in the format of 12:23-23:23.
NOTE: The system forwards only the alarms generated within the time ranges you specified.
For example, if you set 00:0024:00 for a certain day, all alarms generated on the day
are forwarded.
9. Click OK.
Alarm notification 55