HP Intelligent Management Center v5.2 Branch Intelligent Management System User Guide

1. Click the Alarm tab, and then in the CPE Alarm navigation tree click Alarm Notification to
display the alarm notification page.
2. The alarm forwarding rule list provides the following operations:
Click Add to display the Add Alarm Forwarding Rule page.
Click the status link to change the status (Enabled/Disabled) of an alarm forwarding rule.
Click to display the Modify Alarm Forwarding Rule page.
Click to display the Copy Alarm Forwarding Rule page.
Click to delete the alarm forwarding rule.
Click Refresh to refresh the alarm forwarding rule list.
Add/Modify alarm forwarding rule
This function allows you to add or modify an alarm forwarding rule. The system sends alarm
information in the syslog format to the specified server according to the configured alarm forwarding
rule.
NOTE: To add a mail notification, make sure that the mail server is configured properly.
1. Click the Alarm tab, and then in the CPE Alarm navigation tree click Alarm Notification to
display the alarm notification page.
2. Click Add in the Alarm Forwarding area or click for the target alarm forwarding rule.
3. Enter a rule name (for adding an alarm forwarding rule).
NOTE: In an alarm forwarding rule, the logical relationship among the conditions is AND.
4. Enter the destination port number.
5. Select the applicable alarm levels.
NOTE: If you select All Alarms, all types of alarms are forwarded. If you select Selected
Alarms, only the selected alarms are forwarded.
6. Select the applicable CPEs.
NOTE: If you select All CPEs, alarms of all the CPEs are forwarded. If you select Selected
CPEs, only the alarms of the selected CPEs are forwarded.
7. Select the applicable alarms.
8. Enter the time range on each day in the format of 12:23-23:23.
NOTE: The system forwards only the alarms generated within the time ranges you specified.
For example, if you set 00:0024:00 for a certain day, all alarms generated on the day are
forwarded.
9. Click OK.
Copy alarm forwarding rule
Use this function to quickly add a mail notification rule. Based on the configured rule, the system
informs the maintainer of alarms by sending e-mails.
NOTE: To add a mail notification, make sure that the mail server is configured properly.
1. Click the Alarm tab, and then in the CPE Alarm navigation tree click Alarm Notification to
display the alarm notification page.
2. Click of an alarm forwarding rule on the an alarm forwarding rule list to enter the page
for copying the alarm forwarding rule.
Alarm notification 57