Installing and upgrading HP Insight Management 7.2 Update 2 on Windows Server 2012 Failover Clusters

Technical white paper | HP Insight Management 7.2
16
At this point a two-node Failover Cluster has been created, and no clustered services or applications are yet configured. All
relevant Microsoft operating system updates should have been applied to both cluster nodes. Failover Cluster Manager
should produce a display similar to one shown in Figure 4.
Figure 4: Newly created Failover Cluster
Enable 8dot3name (Windows Server 2012 only)
The newly created drive (V:) for Insight Management has 8dot3name disabled by default. The Insight Management DVD
Installer requires the drive to have 8dot3name enabled prior to installing Insight Management on a cluster which is installed
with Windows Server 2012. To enable 8dot3name, execute fsutil 8dot3name set V: 0 .To verify if 8dot3name is enabled,
execute
fsutil 8dot3name query v: and verify the output.
Changing administrator accounts
If you have both administrator accounts configured, log out of the Cluster Administrator account and then log in as SQL/IM
Administrator. This administrator account is used for the remainder of the white paper.
Note:
If HP Matrix recovery management is being installed and configured with HP 3PAR storage on this cluster, the HP 3PAR
Command Line Interface and the HP 3PAR Cluster Extension Software are required to be installed on both cluster nodes. It is
advised to install 3PAR Software on the same Shared drive (V:\ in this whitepaper) where Insight Management will be
installed.